fteu® Air Rectifiers (Quench Units)

Air Rectifiers (Quench Units)

Framed rectifier packs in permeable metal – even, laminar quench air for uniform filaments.

fteu® Air Rectifiers are framed, multi-layer, flowed-through metal packs for the quench units of melt spinning lines. Combining perforated plates, honeycomb and fine mesh or permeable metal layers, they turn turbulent supply air into an even, low-turbulence and laminar quench air flow – the basis for uniform cooling and constant filament quality in POY, FDY, industrial yarn, staple fibre and spunbond production.

  • Even, low-turbulence quench air over the full height and width
  • Uniform filament cooling – constant yarn quality
  • Graded and zoned packs to your quench profile
  • Cross-flow panels and radial quench candles

Compatible with machines and systems from Oerlikon (Barmag) · TMT Machinery · Reifenhäuser (Reicofil)*

Also known as air rectifier · rectifier assembly · quench air rectifier · quench unit · quench screen · quench air screen · quench air diffuser · exhaust quench air diffuser

Technical data

Air Rectifiers (Quench Units) at a glance.

Our standard range – other dimensions and structures on request.

MaterialsStainless steel (e.g. AISI 304 (1.4301), AISI 316L (1.4404)); aluminium honeycomb; permeable metal layers
Filtration gradeFine damping mesh at outlet; permeability graded to quench profile
DimensionsPanels and candles to quench unit; e.g. ring spinnerets approx. 410 mm
Layers / structurePerforated plates (approx. 2–3 mm, 50–70 % open area), honeycomb, fine mesh or permeable metal layers
Edge / connectionWelded frame
Operating limitsUniform velocity profile; low pressure loss

Permeable metal

Every fteu® product starts with the right permeable metal structure. Explore permeable metal →

Applications

Where Air Rectifiers (Quench Units) work.

Main industries, machines and the job the product does there – open an application for details.

Fibres & Textiles
01Cross-flow quench in filament melt spinningCompatible with Oerlikon (Barmag), TMT Machinery*
Industries
Fibres & Textiles
Machines & equipment
POY / FDY / HOY spinning lines: spin beam with spin packs, quench chamber below. Compatible with systems from Oerlikon (Barmag), TMT Machinery*.
Role in the process
Framed rectifier pack evens out the cross-flow quench air over the full height of the filament curtain.
Technical notes
Perforated plates approx. 2–3 mm, 50–70 % open; honeycomb; fine damping screen; stainless steel.
02Radial quench for fine and micro filamentsCompatible with Oerlikon (Barmag)*
Industries
Fibres & Textiles
Machines & equipment
POY / FDY lines with radial quench systems below each spinneret. Compatible with systems from Oerlikon (Barmag)*.
Role in the process
Cylindrical screen pack cools the filaments evenly from all sides.
Technical notes
Cylindrical multi-layer screen; very uniform permeability.
03Cooling air rectification in spunbond linesCompatible with Reifenhäuser (Reicofil), Oerlikon (Neumag)*
Industries
Fibres & Textiles
Machines & equipment
Spunbond and SMS lines with cooling chamber and air distribution. Compatible with systems from Reifenhäuser (Reicofil), Oerlikon (Neumag)*.
Role in the process
Rectifier and flow screens even out the cooling air across the width.
Technical notes
Honeycomb plus inlet and outlet screens; large widths.
04Staple fibre lines with ring spinneretsCompatible with Oerlikon (Neumag)*
Industries
Fibres & Textiles
Machines & equipment
Staple fibre lines with ring spinnerets and radial quench (inside-out or outside-in). Compatible with systems from Oerlikon (Neumag)*.
Role in the process
Quench candle or ring chamber distributes air evenly around the filament bundle.
Technical notes
E.g. ring spinnerets approx. 410 mm Ø; stainless steel.
05Quench for industrial yarnsCompatible with Oerlikon (Barmag)*
Industries
Fibres & Textiles · Automotive
Machines & equipment
Industrial yarn lines for tyre cord, airbag and seat belt yarns. Compatible with systems from Oerlikon (Barmag)*.
Role in the process
Even quench for high-strength yarns.
Technical notes
Uniform velocity profile; robust packs.
06Radial quench candles for coarse titres and profile fibres
Industries
Fibres & Textiles
Machines & equipment
Spinning positions with ring quench heads below the spin pack.
Role in the process
Cylindrical rectifier pack for high hole counts and profile fibres.
Technical notes
Multi-part candles; stainless steel.
07Multi-layer quench diffusers
Industries
Fibres & Textiles
Machines & equipment
Quench diffusers with honeycomb and wire screen layers.
Role in the process
Graded layers produce a uniform outflow.
Technical notes
Honeycomb approx. 6 mm cells; graded fine screens.

* Brand names belong to their respective owners. We supply compatible products and are not affiliated with these manufacturers.

Configurations

Built for your system.

We build the structure your process needs – to drawing, sample or specification.

Flat cross-flow rectifier

Perforated plate, honeycomb and fine screen in a frame.

Radial quench candle

Cylindrical screen pack for outside-in quench.

Inside-out quench candle

Central candle for ring spinnerets.

Graded / zoned rectifier

Permeability profile over the height.

FAQ

Questions about Air Rectifiers (Quench Units).

Short answers to what customers ask us most.

What does an air rectifier do in a quench unit?

It straightens and evens out the supply air so that the freshly spun filaments are cooled uniformly – a key factor for constant yarn quality.

How is an air rectifier built?

Typically from one to three perforated plates, a honeycomb layer and a fine damping screen or permeable metal layer at the outlet, held in a frame.

Cross-flow or radial quench?

Cross-flow units blow air from one side across the filament curtain; radial quench candles cool from all sides – especially for fine and micro filaments.

Do you also repair air rectifiers?

Yes – we clean, refurbish and re-screen quench screens and rectifiers, also with express service.

Send us your drawing or sample.

We make your Air Rectifiers (Quench Units) to fit – from a single piece to series.

Request a quote